E.O.gas sterilizer

Inquire now

E.O.gas sterilizer

Click to enlarge image

 Model Number HS-3041EO

Features

  • The sterilization with gaseous agents serves as the complementary with steam sterilization system used for sterilizing the medical device and materials defying the steam sterilization due to its vulnerability to the high temperature and moisture. Up to now, it is recognized as the sole sterilization system which can replace the steam sterilization method; it is an indispensable equipment for the hospital and the research institutes related with the microorganism.

  • Comtrols

    The Controls System with a built-in microprocessor, controls process of the cycle, the displaying of a large 5"LCD showing the operating conditions of the sterilizer, the self-diagnosis which detects abnormality and takes necessary actions and the printer which printing out the cycle performance records automatically.

  • Cycle program

    As for the sterilization gas, three(3) kinds of gas mixture with carbon dioxide(CO2) and two(2) Freon (CFC, HCFC) can be used and thus the option for using gas is rather wide; it has the built-in four(4) kinds of basic cycles, one(1) test cycle and user cycle whereby the high temperature (56℃)and the low temperature (38℃)can be selectively used.

    The basic cycle is a program generally applied to most to most items to be sterilized.
    The test cycle is a vacuum leak test for airtightness of the chamber.
    The user cycle can be used and saved by changing the temperature, pressure, sterilization time and aeration time at the user's option.

  • Self diangnosis

    The Self-Diagnosis detects 14 malfunctions by itself and displays the error codes and gives the warning signal sound.

  • Vacuum pump

    The vacuum pump is of the diaphragm type with low noise, powerful exhaustion, strong durability and thermal protector.

  • Printer


    It prints a cycle performance record which reviews, analyzes and saves sterilization results related to management. This document includes sterilizer number, date and year, setting value (sterilization temperature, exposure time, and drying time), performance data of each phase (start and finish time, temperature and pressure), maximum / maximum/minimum temperature and pressure, elapse time of each phases, acceptance or unacceptance of the cycle and other data.(cycle time, cycle number, error codes, power failure/recovery time)

Specifications

Overall
W614 xH484 xD792mm
Cabinet
W614 xH442 xD646mm
Chamber
W300 xH300 xD450mm, Capacity: 40.5 liter
Reservoir
Capacity : 3 Liter
Operating Temperature
121°C∼132°C
Basket
Rectangular
Sterilization Agents
Mixtures Of Ethylene Oxide and Inert Gases
12% EO + 88% CFC, 10% EO + 90% HCFC,
20% EO + 80% CO2
Power source
AC 220V, 50/60 Hz
Power Consumption
1.600W
Control
Microprocessor
Vacuum Pump
Flow Rate : 11 liter/min
Display
Dot Graphic Display LCD
Printer
Dot Matrix, 40 Columns, Single Color
Net Weight
91kg


Related Keywords: gas sterilizer